Series HP High Pressure Filters

Standard Features
  • Bypass Valve - to protect filter element, standard setting is 25 PSID (1.72 Bar). Other settings are available.
  • 360° mechanical differential indicator - provides gradual warning of dirty element before bypass valve opens. Standard setting is 20 PSID (1.38 Bar) for full "red" indication. Other settings are available.
  • Mounting holes for convenient installation.
  • Drain plug.
  • Self-aligning element for easy replacement.
  • T-type contruction for more efficient contaminant removal.
  • Cycle tested at 3900 PSI (269 Bar) for 1,000,000 cycles.
  • Filter retention:

5 micron nominal: B5=2.2
10 micron nominal: B10 = 2.1
3 micron nominal: B3 = 200
12 micron nominal: B12 = 200

Optional Features:

  • 360° electro-mechanical differential indicator. Provides gradual warning and electrical signal before bypass opens.
  • Differential taps for remote indicator location.

Applications:

The HP series is designed for high pressure hydraulic systems that require fine filtration. These filters come in three standard sized with continuous working pressure of 3000 PSI (207 Bar) and flows to 60 GPM (227.1 L/min.).


Average Pressure Drop
160 SSU @ 150°F (39°C)
225 SSU @ 85°F (29.4°C)